Model |
J165K |
|
132 KW/165 kVA |
120 kW / 150 kVA |
|
Stand-by Power @ 50 Hz |
Prime Power @ 50 Hz |
| Voltage | HZ | Phase | PF | Stand By Amps | Stand by power kW/kVA | Prime Power kW/kVA |
| 415/240 MONO V | 50 Hz | 3 | 0.8 | 230 | 132/165 | 120/150 |
| 400/230 MONO V | 50 Hz | 3 | 0.8 | 238 | 132/165 | 120/150 |
| 380/220 MONO V | 50 Hz | 3 | 0.8 | 251 | 132/165 | 120/150 |
| 240/120 MONO V | 50 Hz | 3 | 0.8 | 397 | 132/165 | 120/150 |
| 230/115 MONO V | 50 Hz | 3 | 0.8 | 414 | 132/165 | 120/150 |
| 220/110 MONO V | 50 Hz | 3 | 0.8 | 433 | 132/165 | 120/150 |
| 220/127 MONO V | 50 Hz | 3 | 0.8 | 346 | 130/132 | 96/120 |
| 200/115 MONO V | 50 Hz | 3 | 0.8 | 476 | 132/165 | 120/150 |
PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. A 10% overload capability is available for a period of 1 hour within 12-hour period of operation, in accordance with ISO 3046-1
ESP:The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO8528-1. Overload is not allowed.
Call Us on 01794 521355
J165K specifications and design liable to modifications without prior notice
Manufacturer / Model :
6068HF120–153, 4 cycle, Turbo, Air/Air DC
Cylinder Arrangement :
6 X L
Displacement :
6.72L [410.1C.I.]
Bore and Stroke :
106mm [4.2in.] X 127mm [5.0in.]
Compression ratio :
17 : 1
Rated RPM :
1500 Rpm
Piston Speed :
6.35m/s [20.8ft./s]
Max. stand by Power at rated RPM :
150kW [201BHP]
Frequency reg, steady state :
+/-2, 5%
BMEP :
16.3bar [236psi]
Governor type:
Meca
Exhaust gas flow :
385L/s [816cfm]
Exhaust temperature :
555°C [1031°F]
Max back pressure :
750mm CE [30in. WG]
110% (Stand By power ) :
36.5L/h [9.6gal/hr]
100% (of the Prime Power) :
33.5L/h [8.9gal/hr]
75% (of the Prime Power) :
25L/h [6.6gal/hr]
50% (of the Prime Power) :
17L/h [4.5gal/hr]
Total fuel flow :
108L/h [28.5gal/hr]
Total oil capacity w/filters :
21.5L [5.7gal]
Oil Pressure low idle :
1bar [14.5psi]
Oil Pressure rated RPM :
5bar [72.5psi]
Oil consumption 100% load :
0.037L/h [0.0gal/hr]
Oil capacity carter :
20.6L [5.4gal]
Heat rejection to exhaust :
99kW [5629Btu/mn]
Radiated heat to ambiant :
16kW [910Btu/mn]
Heat rejection to coolant :
55kW [3127Btu/mn]
Max. intake restriction :
625mm CE [25in. WG]
Engine air flow :
170L/s [360cfm]
Radiator & engine capacity :
25.8L [6.8gal]
Max water temperature :
105°C [221°F]
Outlet water temperature :
93°C [199°F]
Fan power :
3 kW
Fan air flow(m3/s) :
4.44m3/s [9409cfm]
Available restriction on air flow :
20mm CE [0.8in. WG]
Type of coolant :
Gencool
Thermostat :
82-94 °C(179-201.2°F)
HC(mg/Nm3) :
35 mg/Nm3
CO(mg/Nm3) :
150 mg/Nm3
Nox(mg/Nm3) :
2800 mg/Nm3
PM(mg/Nm3) :
80 mg/Nm3
Call Us on 01794 521355
J165K specifications and design liable to modifications without prior notice
Manufacturer / Type :
LEROY SOMER LSA442M95
Number of phase :
3
Power factor (Cos Phi) :
0.8
Altitude :
<1000 m
Overspeed :
2250 rpm
Pole Number :
4
Exciter type :
Shunt
Insulation class, temperature rise :
H/H
Voltage regulator :
R230
Sustained short circuit current:
–
Total harmonics (TGH/THC)
<4%
Wave form : NEMA = TIF – TGH/THC
<50
Wave form : CEI = FHT – TGH/THC :
<2%
Bearing – number :
1
Coupling :
Direct
Voltage regulation 0 to 100% load :
+/- 1%
Recovery time (20% Volt dip) ms
500 ms
SkVA with 90 % of nominal sustained voltage (at 0.4 PF) :
N/A
Continuous nominal rating @ 40°C :
150 kVA
Standby rating @ 27°C :
165 kVA
Efficiencies @ 4/4 load :
92.1 %
Air flow(m3/s ) :
0.37m3/s [783.98cfm]
Short circuit ratio (Kcc) :
0.42
Direct axis synchro reactance unsaturated (Xd) :
317 %
Quadra axis synchro reactance unsaturated (Xq) :
190 %
Open circuit time constant (T'do) :
2865 ms
Direct axis transient reactance saturated (X'd) :
11 %
Short circuit transient time constant (T'd) :
100 ms
Direct axis subtransient reactance saturated (X''d) :
6.6 %
Subtransient time constant (T''d)
10 ms
Quadra axis subtransient reactance saturated (X''q)
7.8 %
Zero sequence reactance unsaturated (Xo) :
0.3 %
Negative sequence reactance saturated (X2) :
7.3 %
Armature time constant (Ta) :
15 ms
No load excitation current (io) :
0.6 A
Full load excitation current (ic) :
2 A
Full load excitation voltage (uc) :
36V
Recovery time (Delta U = 20% transitoire) :
500ms
Motor start (Delta = 20% perm. Or 50% trans.):
400 kVA
Transient dip (4/4 charge) – PF : 1.8 AR :
14.7%
No load losses :
2.62kW[1.41Kw]
Heat rejection :
10.2 kW
Call Us on 01794 521355
J165K specifications and design liable to modifications without prior notice
Overall size l x w x h : 2370mm [93in] x 1114mm [44in] x 1480mm [58in]
Weight : 1640kg [3615lbs] Net 1980kg [4364lbs] Brut
Overall size l x w x h : 3508mm [138in] x 1200mm [47in] x 1830mm [72in]
Weight : 2110kg [4650lbs] Net 2460kg [5422lbs] Brut